DWG2000C-4/8G User Manual
9 / 51
3. Network Configuration
In this chapter we will introduce the initial configuration of DWG2000C-4/8G. All of the network
parameters of the gateway can be configured by IVR guidance.
3.1 Attentions
In each step, if user hears an IVR message of “setting successful”, which means that user has finished
this step successfully. However, if user hears a “setting failed” message, please re-do that step again.
3.2 General Feature Codes for System Setting
Table 3-3-1 Feature codes for system setting
Set IP address(static/DHCP), a can be digit 1 or 2,*150*1# is static IP address
mode, *150*2# is DHCP mode
Configure IP address, a, b, c, d are the four fields of IP address.
Configure subnet mask. a, b, c, d are the four fields of the subnet mask
Configure the device gateway, a, b, c, d are the four fields of the device gateway
Report LAN port IP address
Report WAN port IP address
Setting the work mode (route or bridge), * 157 * 0 # is route mode, * 157 * 1 # is
bridge mode
Setting Record. dial*199# start record(≤ 20s), then press # end the recording
3.3 Static IP Configuration
This is an optional configuration step. In case of user forgot the IP address or the device can’t obtain IP
address from local network properly, IVR guideline may help to fix it.
Assume that DWG2000C-4/8G IP address to be 172.16.80.89, subnet mask is 255.255.0.0, default
gateway is 172.16.1.1, configure it through IVR as following steps:
1) Please make sure SIM card installed well and registered
2) Dial the phone number of the SIM card. Press "*150*1#" after heard "dial the extension number ".
Hang up after heard “setting successful" prompt.
3) Dial the phone number of the SIM card. Dial "* 152 * 172 * 16 * 80 * 89 #"after heard “dial the